9910 pSeries UPS Technical Specifications
1
5115 = P07; 9125 = P10, P15 P30, P64; 5125 = P18, P22, P33
Electrical
Allowable input range 9125, 5115 120 or 208/240 Vac, model dependent
5125
Input power factor 9125 >.95 typical
5115, 5125 .90 typical @ full load
Output wave form All Models Sine wave
Output regulation 5115, 5125, ±5%
9125 ±3%
Output voltage THD 5115, 5125, 9125 5%, linear load
Load crest ratio 9125 3:1
5115, 5125 N/A
Battery
Battery type All Models Sealed, maintenance-free lead-acid
Recharge time 9125 2 hours to 80% capacity
5115, 5125 <3 hours to 90% capacity
Diagnostics All Models Automatic online test without exposing the
load
General
Architecture 5115, 5125 Line-interactive
9125 True online double-conversion
User interface 9125 8 LEDs indicating system status
5125 5 LEDS indicating system status
5115 4 LEDs indicating system status
Diagnostics All Models Full system self-test on power up
UPS bypass All Models Automatic on overload or UPS failure
Replacement modules 5125 (P33) Hot-swappable batteries and electronics
5115, 5125, Hot-swappable batteries
9125
Communications 5125 (P33) 3 Serial ports
5115, 5125 1 Serial port
(P18, P22), 9125
Networks 5125, 9125 Connectivity via Ethernet is an orderable
option, FC 2934
5115 Connectivity via Ethernet (Thinwire or
Twisted Pair) & Token Ring are orderable
options, FC 2103, 2203, 2303
Safety 9125 UL, CSA, NOM
5115, 5125 UL 1778, CSA-C22.2 No. 107.1;
EN 50091-1, EN 60950
Environmental
Audible noise 5115, 5125 <45 dBA typical
9125 <55 dBA typical
Ambient operating 5115, 9125 0°C to 40°C (32°F to 104°F)
5125 10°C to 40°C (50°F to 104°F)
Relative humidity 9125 5 to 90% non-condensing
5115, 5125 5 to 95% non-condensing
EMC markings 5115, 5125 FCC Class A
9125 FCC Class B and VCCI Class II
1. For additional specifications, see the Model Selection Guide. Due to continuing product improvement
programs, specifications are subject to change without notice.
7029-6C3, 7026-6M1, 7026-6H1,
UPS 7043-43P 7044-44P 7028-6E1 6E3 7025-6F0 7025-6F1 7028-6E4 7028-6C1 7028-6C4 7026-B80 7038-642 6H0 9112
model 150 170, 270 p610 p615 p620 p620 p630 7046-B50 p610 p630 p640 p650 p660 265, 275
P07 x x x x
P10 x x x x x x
P15 x x x x x x x x
P18 xx x x x
P22 x x x x x x x
P30 x x x x x x
P33 xx x xx
P64 x x x x x x
For 7046-671 (p670), 7040-681 (p690) and RS/6000 SP information, contact Powerware.
Choosing the right UPS for your pSeries and IntelliStation
Vista de página 3
1 2 3 4 5 6

Comentários a estes Manuais

Sem comentários